Kühlwasseraufbereitung cooling water treatment
We can be cool too!

Solutions for professional cooling water treatment

Treatment, filling, replenishment and cleaning of cooling water in accordance with VDI 6044, ÖNORM H 5195-1 and SWKI BT 102-01

ein Mann lehnt am Geländer in einer Industriehalle, im Hintergrund ein UWS Gerät zu sehen
Make-up
eine Frau sitzt auf Sand auf einer Baustelle
Cooling water treatment
ein Mann, daneben MAGella als Graffiti auf der Wand
Magnetite separator

Our product range for bivalent cooling water treatment

The water in cooling systems plays the main role in the smooth operation and service life of the system. VDI 6044, ÖNORM H 5195-1 and SWKI BT 102-01 are the working basis for installation, filling and maintenance. On its way through the cooling system, the water comes into contact with almost all parts and can cause massive damage. Within these areas, we are continuously developing efficient solutions for you in practice. It goes without saying that every product is designed for use in accordance with the guidelines in order to guarantee proper cooling water treatment.

Our product range extends from cooling water treatment and filling, to make-up water feeding, magnetite separators and corrosion monitoring.

They treat the cooling water with UWS treatment units, which soften, desalinate and filter at the same time.

Fully demineralized water with mixed bed resin Vadion pH-Control

In order to meet the values recommended in VDI 6044, ÖNORM H 5195-1 and SWKI BT 102-01, we have developed our mixed bed resin Vadion pH-Control. In addition to desalinating the water to < 100 µS/ cm, it also ensures that the pH value of the filling water is within the required range. The removal of existing residual hardness and dissolved salts in the cooling water of a system during operation (bypass process) is possible without any problems.

Mischbettharz Vadion pH-Control
Water hardness, dissolved gases, pH value and conductivity are the decisive parameters

Why
Cooling water treatment?

Scaling, corrosion and magnetite are common causes of damage in the event of problems with the system. For these reasons, VDI 6044, ÖNORM H 5195-3 and SWKI BT 102-01 specify guide values for the cooling water. These form the basis of many warranty conditions – which planners, installers and operators should always keep in mind. If the specified guidelines are not adhered to, there is a risk of:

  • Refusal of commissioning by the manufacturer
  • Refusal of the warranty claim in the event of damage and
  • Performance and efficiency losses
  • Medium/long-term damage to the system.

Contact
find on site:

Capacity calculator for reprocessing units

With our capacity calculator you can easily and quickly calculate the filling capacity of your unit as well as the expected required amount of Vadion pH-Control mixed bed resin. Please select whether it is a new or existing unit.
UWS Füllgerät
Mischbetttauscher
°dH des Wassers
Heizwasser in Liter
Füllkapazität Ihres Gerätes:
Füllwasser Kapazität ca.
20.700 l
Benötigte Gesamtmenge Vadion in Liter ca.
0,11 l